The panels come in the same 25 solid colors as allura s traditional siding as well as in a ready to paint finish.
Allure siding flashing.
Junction flashing is manufactured specifically for fiber cement siding as a weather resistant barrier.
Xxapply siding over a weather resistant barrier in accordance with local building code.
Keep the nails flush to the siding.
Multimax lap siding products offer.
Allura s fiber cement shingles shakes and half rounds are designed to give you a wide range of looks for your home s exterior.
Junction flashing is made of 0 015 primed aluminum with an epoxy backer to protect from corrosion.
The lawsuit complaint says that the cracked siding allows water and moisture to penetrate the siding causing thousands of dollars of water damage.
The allura fiber cement siding should be cut and installed around the trim block leaving a 1 8 gap at the bottom and sides and a 1 4 gap at the top.
Do not caulk the top 1 4 gap.
Get the look of hand hewn cedar shingles with multishake.
An allura siding cracking lawsuit has been filed alleging that allura fiber cement siding cracks within five years of installation.
Position your first course of siding inch below the starter strip and nail the siding into the studs 1 inch down from the top of the siding.
On top of products worthy of the industry s strongest warranty we bring you the important qualities of responsiveness and reliability.
Making the material difference.
Allura fiber cement siding offers a 50 year limited transferable product warranty on all products listed in this document with the exception of lap siding products branded as multimax.
Do not overdrive the nails.
Xxinstall individual shakes over wall construction with framing spaced no more than 24 o c.
The slip fit positioning lip insures quick and.
A common problem with cement board siding products and some other types of horizontal lap siding is that older installation guidelines called for caulking the joint instead of flashing the joint.
Homeowners who had allura siding installed that cracked split warped or fell off may be eligible to participate.
Do caulk bottom and side 1 8 gaps.
Use galvanized siding nails and make sure that the nails penetrate a minimum of 1 1 4 inches into the framing.
And a minimum of 7 16 osb or 1 2 plywood sheathing.
And ccmc technical guide requirements as required by the national building code of canada.
Allura fiber cement siding is tested in accordance with astm1186 in the u s.
These testing standards include a stringent review of more than a dozen properties such as flexural strength moisture movement frost resistance transversal loading and water.
Install a starter strip over the top of the z flashing and the trim block when required to shim gap.
Installation must comply with the requirements of all applicable local state and national code jurisdictions.